ESPECIFICACIÓN: 10006

500-37 CU (253 mm2) SIMpull(R) XHHW-2/RW90 AMARILLO 0 PIES

Southwire #: 55025999

Download Category Specifications
PDF Excel Table
Select Product Specifications
Construcción
Outer Jacket / Armor Color
NEGRO
BLUE
BROWN
GRAY
GREEN
ORANGE
PURPLE
RED
BLANCO
YELLOW
Packaging

Application & Features

APLICACIÓN
Southwire Copper SIMpull XHHW-2®/RW90 conductors are primarily used in conduit, cable tray or other recognized raceways for services, feeders, and branch circuit wiring, as specified in the National Electrical Code. SIMpull XHHW-2®/RW90 copper conductors may be used in wet or dry locations at temperatures not to exceed 90°C. Voltage rating for XHHW-2 conductors is 600 volts or 1000 volts for all sizes. Suitable for use in Health Care Facilities per Section 517.160 of the National Electrical Code where a dielectric constant of less than 3.5 maybe specified. This cable is designed to be installed without the application of pulling lubricant. RW90 is for open wiring and use in raceways (except cable troughs and ventilated flexible cableways) in dry or wet locations as per Canadian Electrical Code. For open wiring exposed to the weather.

CARACTERÍSTICAS
- SIS- 8 AWG
- Resistente a la luz solar
- Curva en frío a -40 °C
- FT1
- Resistente a la gasolina y al aceite II
- Clasificación CT- 1/0 AWG y más grande
- FT4- 350 kcmil y más grande
- Cumple con RoHS/REACH
- SPEC 10005 para tamaños de circuito 14 AWG, 12 AWG y 10 AWG

Specifications

Cond. Tamaño 500 KCMIL 500 KCMIL
Número de conductor 1 1
Cond. Hebras 37 37
Diámetro sobre el conductor (pulg.) (cm) 0,789 2.00 pulgadas cm
Insulation Thickness (mils) (mm) 65 1.65 mils mm
Aprox. OD (pulg.) (cm) 0,908 2.31 pulgadas cm
Copper Weight (lbs/1000') (kgs/km) 1543 2296 lbs/1000' kgs/km
Aprox. Peso (lbs/1000') (kgs/km) 1632 2429 lbs/1000' kgs/km

Standards & References

  • Cable de cobre blando o recocido ASTM B3
  • Conductores de cobre trenzados concéntricos ASTM B8
  • Conductores de cobre trenzados Unilay combinados de 19 hilos ASTM B787
  • Cables y alambres con aislamiento termoconfigurado UL 44
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • CSA C22.2 No. 38 Thermoset-insulated wires and cables
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202/FT4 Flame Test (70,000 BTU/hr) 350kcmil and Larger
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661
  • Especificación federal A-A-59544
  • NMX-J-451-ANCE Thermoset insulated wires and cables
  • NOM-063-SCFI Electrical Products – Conductors – Safety Requirements

Construcción

  1. Conductor: Class B compressed stranded bare copper per ASTM B3 and ASTM B8
  2. Aislamiento: Cross Linked Polyethylene (XLPE) with SIMpull Technology. Silicone-Free, Abrasion, High-Heat, Moisture Resistant
Powered by Translations.com GlobalLink Web Software